Minimal pressure drop, extensive calibration options, and high accuracy. It is unaffected by density, temperature, and viscosity when measuring volumetric flow and has no moving parts; it is characterized by high reliability and low maintenance.
| Dimension | DN15-DN300 | Work environment | -10 +55°C, RH 5% 90% |
| Electrical connection | 1/2NPT, M20x1.5 | Temperature (°C) | -25 +250°C |
| Materiale | SS. Aluminum Alloy | Output signal | analog 4-20 mA-Frequency |
| Power in | 24 VDC | Precision | 1% |
| Standard | Q/320831AHH003-2004 JB/T6807-93 | |
| Fluid | Gas, liquid, vapor | |
| Dimensions | Wafer Type | 25, 32, 50, 80, 100, 150, 200, 250, 300 |
| Flanged type | 100, 150, 200, 250, 300 | |
|
Measurement Range |
Normal flow rate | Reynold number 1.5 * 10^4 ~ 4 * 10^6; gas 5~50 m/s; liquid 0.5~7 m/s |
| Normal reach | Reach liquid, gas, sheet 2 Reach vapor: sheet 3 | |
| Precision | Class 1.5 | |
| Temperature |
Normal -25°~100° High temperature -25°~150° -25°~250° |
|
| Output signal | Output pulse | Onfrom quadra |
| Analog signal | 4 ~ 20 mA, transmission distance 100 m | |
| Environmental conditions | Temperature: -25°~+55° humidity: 5~90% | |
| Material | St.St. - Aluminum | |
| Power in | 24V DC or 3.6V lithium battery | |
| Protection class | IP65 | |
| Nominal Diameter (mm) | 25 | 32 | 50 | 65 | 80 | 100 | 150 | 200 |
| Liquid (m3/h) | 1~10 | 1.5~18 | 4~55 | 6.3~72 | 9~135 | 14~200 | 32~480 | 56~800 |
| Gas (m3/h) | 25~60 | 15~150 | 35~350 | 60~390 | 90~900 | 140~1400 | 300~3000 | 550~5500 |
DIAMETRIC OIL SIZE
Heavy fuel oil, light fuel oil, or gas are used in boilers to produce heat. The diathermic oil circulates, driven by a pump.
Once its calorific value is exhausted, the oil returns directly to the industrial boiler for reheating. This is widely used in the
petrochemical, textile, printing and dyeing, rubber, food, wood, asphalt, coal production, vegetable dehydration, and other industries. Its operating temperature is lower than 350°C.

COMPRESSED AIR MEASUREMENT
Compressed air, transmitted via electrical or thermal energy from a compressor, is an important form of secondary energy in industrial production and an essential savings factor for companies and public administrations: in fact, calculating air at operating conditions allows for significant energy savings and improved plant management. This is the primary purpose of the Vortex flow meter for compressed air.

STEAM MEASUREMENT
Steam is one of the most important energy sources and the most important for central heating in cities. It is a key cost-saving factor for businesses and public administrations. Correct steam flow measurement will directly impact the economics of the steam supplier and the end user. ERRE.DI provides the perfect solution for steam measurement.

20092 Cinisello Balsamo (MI), Via dei lavoratori, 15-19