<- All flow instrumentation

FIXED WALL-MOUNTED ULTRASONIC FLOW METER

A fixed wall-mounted ultrasonic flow meter is a device used to measure the flow of liquids or gases through pipelines without interrupting the process or cutting into the pipeline itself. This type of flow meter uses ultrasound technology to determine the velocity of the fluid inside the pipeline and calculate the total flow.

The JC-3000B Reach Meter offers extensive measurement capabilities. The converter has an IP67 protection rating, while the transducers are IP68. Measurement is possible on a wide range of liquids in a large number of applications: ultrapure liquids, drinking water, chemical and petroleum products, sewage, reclaimed water, cooling water, river water, plant wastewater, etc.

DOWNLOAD THE TECHNICAL DATA SHEET

Measuring flow Heat measurement Characteristics
Clamp - on
  • No need to interrupt the flow, no pressure drop.
  • To measure heat/energy, simply connect a temperature sensor, even a clamp-on type.
  • Easy installation.
Insertion
  • No flow interruption required, no pressure drop.
  • Stable and reliable for continuous operation.
  • To measure heat/energy, simply connect a PT100 temperature sensor.
Tube
  • It is necessary to interrupt the flow.
  • Great precision and stability.
  • To measure heat/energy, simply connect a PT100 temperature sensor.


Optional transducers
Choose the transducer type based on the characteristics of the liquid, the pipe, and the installation method (see measurement type).
Type Spec. Template Measurement range Temperature Dimension
Clamp-on Small TS-2 DN25~ DN100 -30~ 90 °C 45×25×32mm
Medium TM-1 DN50~ DN700 -30~ 90 °C 64×39×44mm
Big TL-1 DN300~ DN6000 -30~ 90 °C 97×54×53mm
Clamp-on for high temperatures Small TS-2-HT DN25~ DN100 -30~ 160 °C 45×25×32mm
Medium TM-1-HT DN50~ DN700 -30~ 160 °C 64×39×44mm
Big TL-1-HT DN300~ DN6000 -30~ 160 °C 97×54×53mm
By insertion Standard TC-1 DN80~ DN6000 -30~ 160 °C 190×80×55mm
Elongated TC-2 DN80~ DN6000 -30~ 160 °C 335×80×55mm
Tube π tipo G1 DN15~ DN32 -30~ 160 °C Threaded SUS304
Refer to the pipe dimensional details
Standard G2 DN40~ DN100 -30~ 160 °C Threaded carbon steel


Transducers of temperature opzionali
Specifications Model Measuring range Temperature Flow interrupter Precision
Transducer of temperature clamp-on PT100 CT-1 >DN50 -40~160°C No 100°C ±8.0°C
Transducer of temperature by insertion PT100 TCT-1 >DN50 -40~160°C Yes
PT100 by insertion, pressure installation PCT-1 >DN50 -40~160°C No
PT100 by insertion, for small diameter pipes SCT-1 >DN50 -40~160°C Yes